Gold Member Since 2006
Audited Supplier
Weifang Hongyuan Waterproof Materials Co., Ltd.

Sbs Membrane, Waterproof Membrane manufacturer / supplier in China, offering 1.5mm Sbs Modified Bitumen Membrane, Waterproofing Membrane/EPDM Roof Waterproof Membrane/EPDM Pond Liner, Asphalt Shingle/Roof Tiles/Roof Materials and so on.

(/ )

Supplier Homepage Product sbs/app bitumen waterproof membrane 1.5mm Sbs Modified Bitumen Membrane

1.5mm Sbs Modified Bitumen Membrane

FOB Price: Get Latest Price
Min. Order: 10,000 Square Meters
Port: Qingdao, China
Production Capacity: 5000000squre Meters/Year
Payment Terms: L/C, T/T

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Type: Waterproof Roll Material
  • Material: Modified Bitumen
  • Ceiling Tile Type: Fiberglass Ceilings
  • Function: Waterproof
  • Color: Black
  • Trademark: hongyuan
  • Specification: 3mm*1m*15m
  • HS Code: 68079000
  • Ceiling Tile Shape: Roll
  • Thickness: 3.0mm
  • Surface Treatment: Film Coated
  • Certification: ISO, MSDS, CE
  • Usage: Outdoor
  • Transport Package: Pallets
  • Origin: China
Product Description
SBS/APP modified bitumen membrane
SBS modified bitumen membrane is made by saturating the base in bitumen, or thermoplastic elastomer (such as styrene butadiene-SBS), reinforced with polyester or fiberglass, finishing the upward face with fine sands, mineral slates(or grains) or polythene membrane etc.
APP modified bitumen membrane is made by saturating the base in bitumen, or thermoplastics (such as APP,APAO,APO), then covering double faces with thermoplastic elastomer (SBS) and last finishing the upward face with fine sands, mineral slates(or grains) or polythene membrane etc. while downward face with fine sands or polythene membrane.
Characteristic
Good impermeability. Possess good tensile strength, elongation rate and size stability which could be well suited the substrate distortion and crack.SBS modified bitumen membrane is specially being applied in the cold area with low temperature, while APP modified bitumen membrane is applied in the hot area with high temperature. Good performance in anti-puncture, anti-broker, anti-resistance, anti-erosion, anti-mildew, anti-weathering. Construction is convenient, the melt method can operate in four seasons, joints are reliable
Specification
ItemTypePY  Polyester
G  Glassfibre
PYG  Glassfibre enhance polyester felt
PE  PE Film
S  Sand
M  Mineral
GradeIII
ReinforcementPYGPYG
SurfacePESanMineral
Thickness2mm3mm4mm5mm
With1000mm
Applicable scope
Suitable for civil building roofing, underground, bridge, parking, pool, tunnel in the line of waterproofing and damp proof, especially for the building under high temperature. According the roofing engineering stipulation, APP modified bitumen membrane could be used in the Grade civil building and industrial building which has special waterproofing requirement.
Storage and transportation instructions
When storage and transportation, Different types and sizes of products shall be stacking separately, should not be mixed. Storage temperature should not be above 50°C, the height is not more than two layers, in the course of transportation, membrane must stand.
The stacking height is not more than two layers. To prevent the tilt or pressure, when necessary cover the felt fabric.
In normal conditions of storage and transportation, storage period is a year since the date of production
 
 
 
Technical data
SBS                                      [Confirming to GB 18242-2008]
No.Item  
PYGPYGPYG
1Soluble content/(g/m ²)≥3cm2100*
4cm2900*
5cm3500
Test*No flame*No flame*
2Heat resistanceºC90105
≤mm2
TestNo flow, no dripping
3Low temperature flexibility/ºC-20-25
No crack
4Impermeability 30 minutes0.3MPa0.2MPa0.3MPa
5TensionMaximum/(N/50mm) ≥500350800500900
Secondly-Maximum****800
TestNo crack, no apart
6ElongationMaximum/%≥30*40**
Secondly-Maximum≥**15
7Oil LeakingPieces≥2
 
 
APP                                      [Confirming to GB 18242-2008]
No.Item  
PYGPYGPYG
1Soluble content/(g/m²)≥3cm2100*
4cm2900*
5cm3500
Test*No flame*No flame*
2Heat resistanceºC110130
≤mm2
TestNo flow, no dripping
3Low temperature flexibility/ºC-7-15
No crack
4Impermeability 30 minutes0.3MPa0.2MPa0.3MPa
5TensionMaximum/(N/50mm) ≥500350800500900
Secondly-Maximum****800
TestNo crack, no apart
6ElongationMaximum/%≥30*40**
Secondly-Maximum≥**15
 
Construction Points
Construction methods--hot melt, cold and hot adhering methods could be adopter to adhere sheets and substrates, or different sheets. While constructed with hot melt method, the thickness of membrane must be over 3mm. If constructed with cold adhering method, the thickness of cold adhesive must be 0.5-1mm.
Substrate preparation--waterproofing substrates shall be flat, solid, and be dried sufficiently.Detail structures shall meet requirements of related stipulations and designs.
Waterproofing layer--there are two kinds of structures of laminated and single layers,for laminated layers, thickness of each layer shall be not lower than  3mm, with complete adhesion between each other.For single layer,thickness of the single layer shall not be lower than 4mm.
    Overlapping--overlapping between sheets shall be completely adhered, with 80-100mm  width of jointed area.  
Vertical surface ends--fasten with metal battens and bolts, coat special sealant in all edges.
Protection isolation layer construction--protection isolation layer shall be set on the exterior surface of waterproof layers according to related stipulations and designs, if use shale sheets or mineral mineral grain coating surfaces as exposed waterproof layers,additional protective layer could be omitted. Isolation layers shall be set between waterproof layers and rigid protective layers.
Attentions for Construction
Construction shall not be carried out be carried out in rain,snow or over 5 degree wind weather.
There shall be sufficient safety protective facilities in construction site,place firefighting devices according to stipulations.
Installation Sketch point
Clean the substrate using broom or high pressure dusty cleaner.
Apply primer
Heat membrane bottom using a high temperature flame gun.
Push forward while the primer and membrane oil melted.
Use roller to push hard the membrane surface to ensure it stick firmly.
Main point of construction plans
Membrane waterproof of underground structure
Membrane waterproof structure of pond
Roofing waterproof membrane structure
Road and bridge construction waterproof membrane
 
You Might Also Like
Send your message to this supplier
Avatar
Mr. ellen
*From:
To: Mr. ellen
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now